Hoover DYNAMIC NEXT DX C9DG-80 Condenser Tumble Dryer TCE01 Error code 21 with all flashing lights

December 29, 2020
Customer Question

Dryer was running normally until it stopped and started showing an error code with e21 and all the led options flashing. We've cleaned out the lint trap, water container and the condenser but there has been no change. Only got the machine in may

Paul
Paul Repair Expert

I will try and help with this problem Hoover DYNAMIC NEXT DX C9DG-80 Condenser Tumble Dryer

as you will see in the exploded diagram below there are a few thermostats you need to check them, the most common one to fail is the 206c cutout on the heater. also check the heater that there is continuity on both sides of the element as this has high heat and low heat if all of these are good then you may have a problem with the relay on the circuit board. I have included some useful videos for you to watch below, and also an exploded diagram showing you all the parts on the machine all these are available in the links below

I have also included for future reference a full list of error or fault codes on this machine

If you want to support the site please mark us to your favourites, also I would be grateful if you would subscribe to our social media channels as this really helps my site and keeps us going.

YouTube. http://www.youtube.com/user/howtorepair
Facebook. https://www.facebook.com/how.to.repair.appliances
And if we really helped you save money you can always click on the Buy Paul a Beer page

 

Hoover DYNAMIC NEXT DX C9DG-80 Condenser Tumble Dryer spare parts

Hoover DYNAMIC NEXT DX C9DG-80 Condenser Tumble Dryer error and fault codes

E03 Tank is full of water and has to be emptied.
E05 Front NTC sensor is either short circuit or open circuit. Check front NTC sensor and/or
wiring.
E07 Alarm, filter occluded, This error can only appear after the end of a cycle. The filter is
occluded because of fluff presence, the correct ventilation is not allowed. Clean the filter.
E08
Thermo fuse intervention. Replace the thermo fuse and check that ventilation circuit is
clean, check the wiring.
E10 Missing communication between "Cuore" Electric Module and Display Electric Module and/or
Wiring.
E11
In the rear part of condenser the temperature is too high. Check that all ventilation ducts
are clean, check that ventilation system is working well. Check the condenser, the motor,
the fan could be broke/blocked.
E12 Pressure switch doesn’t work. Check the pressure switch and/or wiring. Check that the air
trap is clean.
E13 Compressor NTC Probe is either Short Circuit or Open Circuit. Check the compressor NTC
probe and/or wiring.
E14
Rear NTC Probe is either Short Circuit or Open Circuit. Check the rear NTC probe and/or
wiring.
E15 Main board not programmed. Program the main board.
E19
It is not possible to use NFC tag for any actions until the next POWER ON/OFF. (switch off
and switch on)
E21
Heater control relay on the “cuore” electric module is not working. High temperature has
been reached – Thermo Fuse worked. Check the thermo Fuse, and the wiring. Check that
both the ventilation circuit and ventilation ducts are clean and duct is not obstructed.
Replace the “cuore” electric module only in the case that the heater command relay is
faulty.
E22
Compressor control relay on the “cuore” electric module is not working. Check the
compressor and compressor wiring/connections. Replace the “cuore” electric module only
in the case that the compressor command relay is faulty.