Hoover Dynamic DX C10TCE-80 Tumble dryer Next Trips RCD as soon as switched on at socket

December 28, 2020
Customer Question

RCD tripped taking out all of the downstairs power while dryer was running.Process of elimination pointed at dryer. As soon as I plug in and switch on the RCD goes again. Could it be a mains filter? If so, where is it? PS, I’m a spark by trade.

Paul
Paul Repair Expert

I will try and help with this problem Hoover Dynamic DX C10TCE-80 Tumble dryer

 

this may be a problem with the heating system or there's a possibility that you have a direct short on the tumble dryer this can be caused by components like the motor or possibly a direct short on a Wire.

I have put a full list of parts for this tumble dryer below and also an exploded diagram to help you understand how the machine is put together I have also put some useful videos to assist you and you'll repair

 

 

If you want to support the site please mark us to your favourites, also I would be grateful if you would subscribe to our social media channels as this really helps my site and keeps us going.

YouTube. http://www.youtube.com/user/howtorepair
Facebook. https://www.facebook.com/how.to.repair.appliances
And if we really helped you save money you can always click on the Buy Paul a Beer page

 

Hoover Dynamic DX C10TCE-80 Tumble dryer spare parts

Error & Fault codes for Hoover Dynamic DX C10TCE-80 Tumble dryer

E03 Tank is full of water and has to be emptied.

E05 Front NTC sensor is either short circuit or open circuit. Check front NTC sensor and/or

wiring.

E07 Alarm, filter occluded, This error can only appear after the end of a cycle. The filter is

occluded because of fluff presence, the correct ventilation is not allowed. Clean the filter.

E08

Thermo fuse intervention. Replace the thermo fuse and check that ventilation circuit is

clean, check the wiring.

E10 Missing communication between "Cuore" Electric Module and Display Electric Module and/or

Wiring.

E11

In the rear part of condenser the temperature is too high. Check that all ventilation ducts

are clean, check that ventilation system is working well. Check the condenser, the motor,

the fan could be broke/blocked.

E12 Pressure switch doesn’t work. Check the pressure switch and/or wiring. Check that the air

trap is clean.

E13 Compressor NTC Probe is either Short Circuit or Open Circuit. Check the compressor NTC

probe and/or wiring.

E14

Rear NTC Probe is either Short Circuit or Open Circuit. Check the rear NTC probe and/or

wiring.

E15 Main board not programmed. Program the main board.

E19

It is not possible to use NFC tag for any actions until the next POWER ON/OFF. (switch off

and switch on)

E21

Heater control relay on the “cuore” electric module is not working. High temperature has

been reached – Thermo Fuse worked. Check the thermo Fuse, and the wiring. Check that

both the ventilation circuit and ventilation ducts are clean and duct is not obstructed.

Replace the “cuore” electric module only in the case that the heater command relay is

faulty.

E22

Compressor control relay on the “cuore” electric module is not working. Check the

compressor and compressor wiring/connections. Replace the “cuore” electric module only

in the case that the compressor command relay is faulty.