AEG T65170AV Vented Tumble Dryer Only Dries On 30 Min Setting Not On the Preset Dryness Setting
I have an AEG T65170AV Vented Tumble Dryer. When set to the cupboard dry etc settings machine rotates but no heat is provided. On the 30 mins timed setting, drying occurs. Suspect humidity sensor failed.
Hi Bruce,
Thanks very much for sending the information in regarding your AEG T65170AV Vented Tumble Dryer. I agree with your diagnostic procedure. If the tumble dryer works on a timed programme but not on a preset dryness setting, the humidity sensor may be involved, as timed programmes normally bypass it.
Check that both connections are secure at the back of the humidity sensor, and clean the sensor with a green kitchen scourer. A film can build up on the sensor and give the control board a false reading, preventing the dryer from working correctly. I have also seen the wires come loose from the back of the sensor.
Accessing the sensor can involve quite a lot of dismantling. Before taking the machine apart, you may be able to trace the wires back towards the control board and check continuity between the sensor inside the drum and its connection on the board. Disconnect the dryer from the mains before carrying out any checks, and only test continuity with the circuit isolated.
I have made a video about these humidity sensors, which is well worth watching on our YouTube channel. If you need any further help, feel free to use the contact number included with the link to this article.
Apologies for the delayed reply. I have been inundated with work helping customers, and I am also working on one of the biggest building projects I have taken on in years: creating an off-grid environmental workshop. I’ll be sharing more about it in future videos.
Service Documents
Parts for This Model
Showing compatible parts for model T65170AV